# m06 ## Mouse Physiologic Parameters * Sex: Female * Strain: B6C3F1 * Weight (g): 21.0 * Vendor: Charles Rivers * Physical abnormalities: none * Protocol (https://cebs-ext.niehs.nih.gov/cahs/file/lapd/pages/Core/Animal%20Model.pdf) ## Aerosol Dosing * Particle size: 1 micron * Exposure time: 10 minutes * Exposure estimate: 1.24E+08 FMS | Time | RR (bpm) | Vt (ml) | VE (ml/min) | I:E | |:------------------|---------:|--------:|------------:|-----:| |Pre Aerosol | 133 | 0.16 | 20.9 | 1.00 | |Post 5 Aerosol | 164 | 0.16 | 25.8 | 0.97 | |Post 10 Aerosol | 201 | 0.27 | 55.2 | 0.93 | ## Slicing Info * Approximate lung orientation: LAS * Camera: D7100, 14-bit, 200mm Nikkor Macro lens, f/16 * Voxel size: 4.64 x 4.64 x 9.52 (microns) * Image exposures (msec). ISO=160, all images. | | mt | ol | fl | rd | Notes | |:--------:|:---------:|:-------:|:-------:|:-------:|:----------------------| |excitation| UVND2 | UVND2 | 485/20 | 560/20 |center wavelength/fwhm | |emission | N/A | 470/30 | 535/30 | 635/30 | (nm) | |**Image** |**Exp** |**Exp** |**Exp** |**Exp** | **Notes** | |white | 25 | 125 | 6000 | 167 | 1 drop rhodamine B/10mL OCT | |cal | 20 | 50 | 40 | 200 | | |images | N/A | 50 | 15000 | 333 | | |darks | | 50 | 15000 | 333 | | * Notes regarding slicing: * Sample broke before embedding so the trachea is very short and port of the tracheal wall is missing at the top of the sample. * Problem with camera focus around slices 661-664. * Two fiducial markers are missing before slicing was finished. ## Airway Segmentation * Total centerline length: 605.276 mm * Number of branches: 1670 * Number of terminal branches: 839 * Maximum generation number: 25 * Number of outlet areas: 1912 ## Compartment Sizes and Aerosol Deposition * Lung volume: 1103.35 (mm^3) Compartments | Count | Volume (mm^3) ------------ | ----- | ------------- Lung | 1 | 1103.35 Lobes | 5 | 220.67±94.33 Sublobes | 53 | 20.18±19.19 Near acini | 386 | 2.68±1.36 Lobe | Volume (mm^3) | Average aerosol deposition --------- | ------------- | ---------------------- left | 356.26 | 1.29±1.33 cranial | 183.37 | 1.34±1.32 middle | 144.45 | 1.15±0.99 caudal | 306.23 | 1.12±1.01 accessory | 113.04 | 0.88±0.84 ## Additional Notes * Overall quality: B * Fiducial markers were not visible to the very end of the sample leading to some larger displacements * Sample broke before embedding, breaking off part of the trachea. Segmented trachea piece is very short.